Tank on Tank

Tank on Tank

Single Heat Exchanger with Buffer Tank / Vertical Floor Standing
  • Made from high grade AISI 444 stainless steel, extremely resistant to pitting corrosion
  • All welds are butt welded
  • Made by high quality welding process TIG (GTAW), eliminating the possibility of crevice corrosion
  • The complete tank is pickled and passivated both inside and outsider
  • No sacrificial anodes required
  • Thick insulation polyurethane foam layer - λ = 0,022 W/mK

Pre plumbed DHW tank and buffer tank

The buffer is built into the tank which adds to its attractive aesthetics and system efficiency an improving system flow rate that allows for the heat pump to run for longer reducing the number of times it needs to turn on and off

A tank with coil and buffer is one of the most efficient solutions for DHW and buffer tanks

The benefits include a smaller environmental footprint, a reduction of pipe work and labor

Tank on Tank

Technical informations

Capacity (l) 260L 290L 390L
Dimensions (mm)
A - Diameter 550 580 620 660 620 660
B - Height 1980 2010 1700 1730 2150 2180
Connections
1 Cold Water Inlet 1''F 1''F 1''F
2 Hot water Outlet 1''F 1''F 1''F
3 Secondary Return ¾''F ¾''F ¾''F
4 Heat Exchanger Inlet - Heat Pump 1''F 1''F 1''F
5 Heat Exchanger Outlet - Heat Pump 1''F 1''F 1''F
6 Immersion heater 1½''F 1½''F 1½''F
7 Direct Connection 1''F 1''F 1''F
8 Temperature Sensor ½''F ½''F ½''F
9 Air bleed ½''F ½''F ½''F
Technical Data
Tank Construction *1 Stainless steel DUPLEX LDX 2101 (1.4162)
Rated DHW storage tank (l) 200 200 300
Rated Buffer storage tank (l) 60 90 90
Heat Exchanger Material Stainless steel tube AISI 316L (1.4404)
Heat Pump Heat Exchanger Surface area (m²) 2,5 2,5 3
Heat Pump Heat Exchanger Volume (l) 11,4 11,4 13,6
Heat Pump Heat Exchanger Rated Output (kW) *2 12 / 70 12 / 70 14 / 80
Electrical Backup (W x 230V AC) - OPTIONAL 1500 2000 3000
Insulation – Rigid Polyurethane (mm) 50 65 50 70 50 70
Outer Casing Powder Coated Galvanized Steel
Max. Working pressure - tank (bar) 6 6 6
Max. Working pressure - heat exchanger (bar) 6 6 6
Max. Working temperature - tank (°C) 80 80 80
Max. Working temperature - heat exchanger (°C) 95 95 95
ErP Label C B C B C B
Standby Losses 80W 63W 90W 66W 98W 76W

*1 - Other Alloys Available
*2 - Heat Pump: Primary 65-60°C; Secondary 59-15°C / Boiler : Primary 80-65°C; Secondary 60-15°C