DHW Hygienic Tank

DHW Hygienic Tank

DHW Heat Exchanger / Vertical Floor Standing
  • Made from high grade Duplex LDX 2101 stainless steel, extremely resistant to pitting corrosion
  • All welds are butt welded
  • Made by high quality welding process TIG (GTAW), eliminating the possibility of crevice corrosion
  • The complete tank is pickled and passivated both inside and outsider
  • No sacrificial anodes required
  • Thick insulation polyurethane foam layer - λ = 0,022 W/mK

Combined Buffer & Domestic Hot Water (DHW) and heating

Stainless-steel: coil where domestic hot water is heated instantaneously as it flows through, rather than stored.

Legionella Prevention: Since domestic hot water is produced in a continuous flow rather than kept in a large volume at a warm temperature, the risk of bacterial growth (e.g., Legionella) is significantly reduced.

Multiple Heat Sources: It may incorporate connections and additional heat exchangers to integrate solar thermal systems, heat pumps, wood/pellet boilers, or other conventional boilers. buffer tank stores hot water so that you can get instant hot water anywhere in the house, even if your heat pump is slower heating up the water.

DHW Hygienic Tank

Technical informations

Capacity (l) 200L 300L 400L 500L
Dimensions (mm)
A - Diameter 550 580 620 660 710 760 710 760
B - Height 1420 1475 1570 1700 1560 1580 1910 1940
Connections
1 Cold Water Inlet 1''F 1''F 1''F 1''F
2 Hot Water Outlet 1''F 1''F 1''F 1''F
3 Air Bleeder ¾''F ¾''F ¾''F ¾''F
4 Direct Tapping 1¼’’F 1¼’’F 1¼’’F 1¼’’F
5 Temperature Sensor ½’’F ½’’F ½’’F ½’’F
6 Immersion heater 1½''F 1½''F 1½''F 1½''F
Technical Data
Tank Construction *1 Stainless steel DUPLEX LDX 2101 (1.4162
DHW Heat Exchanger Material Stainless steel corrugated tube AISI 316L (1.4404)
DHW Heat Exchanger Surface Area (m²) 2,3 2,3 3,0 3,0
DHW Heat Exchanger Volume (l) 10,5 10,5 13,7 13,7
Electrical Backup (W x 230V AC) - OPTIONAL 1500 2000 3000 3000
Insulation – Rigid Polyurethane (mm) 50 65 50 70 50 75 50 75
Outer Casing Powder Coated Galvanized Steel
Max. Working Pressure – Tank (bar) 8 8 8 8
Max. Working Temperature - Tank (°C) 80 80 80 80
Max. Working Pressure – Heat Exchanger (bar) 8 8 8 8
Max. Working Temperature – Heat Exchanger (°C) 95 95 95 95
ErP Label C B C B C B C B
Standby Losses 77W 56W 94W 68W 102W 73W 111W 82W

*1 - Other Alloys Available